Manual Cold Feed Water Softener 8 litre, 12 litre or 16 litre
A water softener for dishwashers, glass washers, or small boilers to prevent scale formation caused by hard water
These manual fill cold water softeners can be used for great results on small dishwashers and glasswashers. Simple installation and no electrical point needed. The system works by manually flushing the resin beads with a salt solution as and when required. The range contains 3 models that can soften water between 900 and 1800 litres between regenerations.capacity based water hardness of 20º Clarke/ 180 ppm
- Feed water pressure 1 bar - 8 bar
- Feed water temperature 4 -15°C
- 12 month parts warranty
- Made of 18/8 stainless steel
- Choose the size you require - 8, 12 or 16 litre
In order to guarantee the performance of your softener (the resin) it is necessary to:
-Fill up the softener with drinking water at room temperature and wait for a minimun of two hours.
-Then, rinse (possibly upstream) during 30 minutes at least, in order to get perfectly clean water at the outlet.
When the water softener is found saturated and does not decalcify any more, it must be regenerated.
Regeneration shall be performed at a regenerative capacity of 250 gr of NaCl (bay salt) per litre of resin used.
Here are the salt quantities to be added depending on the water softener model:
D-8 1kg
D-12 2kg
D-16 3kg